BHJKP - BLACK DEVELOPER FOR DC111, ETC
- MSDS: BHJKP
- Manufacturer: MITA COPYSTAR AMERICA INC
- Product Name: BLACK DEVELOPER FOR DC111, ETC
- National Stock Number: 6850-01-243-9292
Product Identification
Product ID:BLACK DEVELOPER FOR DC111, ETC
MSDS Date:03/01/1990
FSC:6850
NIIN:01-243-9292
MSDS Number: BHJKP
Responsible Party
FAIRFIELD (FORMALLY IN HASBROUCK HEIGHTS, NJ 07004-0008
US
Emergency Phone: 201-808-8444
Info Phone: 201-808-8444
Cage: 0AH08
Contractor
Telephone: 201-288-6900
Cage: 65678
Ingredients
IRON OXIDE
CAS: 1309-37-1
RTECS: NO7400000
Fraction By Weight: 70%
OSHA PEL 10 MG/M3 (FE)
ACGIH TLV: 5 MG/M3(FE),B2; 9293
ZINC OXIDE
CAS: 1314-13-2
RTECS: ZH4810000
Fraction By Weight: 10%
OSHA PEL 15MG/M3 TDUST/5 FUME
ACGIH TLV: 10MG/M3 TDUST; 9293
MAGNESIUM OXIDE
CAS: 1309-48-4
RTECS: OM3850000
Fraction By Weight: 5%
OSHA PEL 15 MG/M3 PARTICULATE
ACGIH TLV: 10 MG/M3;TDUST; 9293
CUPRIC OXIDE
CAS: 1317-38-0
RTECS: GL7900000
Fraction By Weight: 5%
OSHA PEL 1 MG CU/M3
ACGIH TLV: 1 MG CU/M3
BLACK TONER FOR DC-111
Fraction By Weight: 10%
Hazards
LD50 LC50 Mixture:ORAL RAT LD50 IS NOT KNOWN
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:PRODUCT IS PRACTICALLY NON-TOXIC. IT
PRODUCES PHYSICAL IRRITATION OF BODY TISSUES. RESPIRATORY
IRRITATION MAY OCCUR IF LARGE AMOUNTS OF DUST ARE INHALED.
Explanation of Carcinogenicity:THE PRODUCT CONTAINS NO INGREDIENT THAT
IS LISTED BY IARC, NTP OR OSHA AS A CARCINOGEN.
Effects of Overexposure:EYE:PHYSICAL IRRITATION SKIN:POSSIBLE
IRRITATION INHALED:RESPIRATORY IRRITATION WITH EXPOSURE TO LARGE
AMOUNTS OF DUST. INGESTED:NOT REPORTED.
Medical Cond Aggravated by Exposure:NONE REPORTED
First Aid
First Aid:EYE:FLUSH W/WATER 15 MIN, HOLD LIDS OPEN. SKIN:WASH WITH
SOAP & WATER. REMOVE CONTAMINATED CLOTHING AND LAUNDER BEFORE
REUSE. INHALED:REMOVE TO FRESH AIR. RESTORE BREATHING IF
NECESSARY. INGESTED:D O NOT INDUCE VOMITING. GIVE 2 LARGE GLASSES
OF MILK OR WATER AND GET IMMEDIATE MEDICAL CARE. GIVE NOTHING BY
MOUTH IF UNCONSCIOUS. IF IRRITATION PERSISTS OR IS SEVERE,SEE A
DOCTOR.
Fire Fighting
Flash Point:NOT RELAVANT
Extinguishing Media:USE CARBON DIOXIDE,
Fire Fighting Procedures:WEAR FIRE FIGHTING PROTECTIVE EQUIPMENT AND A
FULL FACED SELF CONTAINED BREATHING APPARATUS. COOL FIRE EXPOSED
CONTAINERS WITH WATER SPRAY. CONTAIN RUNOFF.
Unusual Fire/Explosion Hazard:COMBUSTION OR HEAT OF FIRE MAY PRODUCE
HAZARDOUS DECOMPOSITION PRODUCTS AND VAPORS.
Accidental Release
Spill Release Procedures:SWEEP UP BEING CAREFUL TO CREATE AS LITTLE
DUST AS POSSIBLE OR VACUUM.
Neutralizing Agent:NONE
Handling
Handling and Storage Precautions:STORE IN A COOL, DRY, DARK AREA. KEEP
TIGHTLY CLOSED.
Other Precautions:NONE
Exposure Controls
Respiratory Protection:RESPIRATOR WILL NOT NORMALLY BE NECESSARY. USE
NIOSH/MSHA APPROVED RESPIRATOR FOR DUST IF EXPOSURE IS ABOVE THE
TLV/PEL FOR NUISANCE DUST.
Ventilation:NOT NORMALLY REQUIRED.
Protective Gloves:NONE
Eye Protection:SAFETY GLASSES
Other Protective Equipment:NONE REQUIRED
Work Hygienic Practices:USE OF GOOD PERSONAL HYGIENE PRACTICES IS
SUFFICIENT. AVOID INHALATION,INGESTION OR SKIN CONTACT IF POSSIBLE.
Supplemental Safety and Health
BLACK DEVELOPER IS USED FOR MODELS
DC-211,213RE,313Z,313ZD,4055,4085,2105.
Chemical Properties
HCC:N1
Spec Gravity:POWDER
pH:UNKNON
Solubility in Water:NEGLIGIBLE
Appearance and Odor:FINE BLACK POWDER, PRACTICALLY ODORLESS
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS
Stability Condition to Avoid:NONE GIVEN BY MANUFACTURER (SUPPLIER).
Hazardous Decomposition Products:NONE GIVEN BY MANUFACTURER (SUPPLIER).
Disposal
Waste Disposal Methods:DISPOSE I/A/W ALL FEDERAL, STATE AND LOCAL
REGULATIONS. DGSC-SSH SUGGESTS THAT DISPOSAL MAY BE DONE AS THOUGH
PRODUCT WERE ORDINARY REFUSE.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.